Technical guide

How to size the right steam boiler for your plant

An undersized boiler stops production and an oversized one wastes fuel. Here are the practical steps to estimate the right capacity.

How to size the right steam boiler for your plant

An undersized boiler stops production at peak times, while an oversized one cycles on and off, wasting fuel and shortening burner life. Here are the practical steps to estimate the right capacity in kilograms of steam per hour.

1. Add up the consumption of every consumer

List every piece of equipment that uses steam (kettle, dryer, heat exchanger, dyeing machine…) with its consumption in kg/h from the nameplate or the manufacturer’s catalogue.

2. Account for simultaneous use and peaks

Equipment rarely runs at full load at the same moment. Identify which consumers run together at the toughest point of the day and size for that. Also watch start-up periods, when demand is higher.

3. Add losses and a safety margin

Add pipe losses, leaks and a safety margin — typically 15–25% — and take any planned expansion over the coming years into account.

4. Define the required pressure

Pressure sets the saturated steam temperature: about 175 °C at 8 bar(g) and about 184 °C at 10 bar(g). Choose the pressure for the highest temperature your processes need, plus a small margin.

Worked example

ConsumerConsumption (kg/h)
Cooking kettle600
Heat exchanger400
Washing & sterilising line300
Total1,300
With a 20% margin≈ 1,560

Result: a 2 t/h steam boiler covers today’s demand with room to grow.

Useful conversions

  • 1 t/h of steam ≈ 0.65–0.7 MW (depending on pressure and feed-water temperature).
  • 1 boiler horsepower (BHP) ≈ 15.65 kg/h of steam, so 1 t/h ≈ 64 BHP.

Tip: if downtime is costly, consider two smaller boilers instead of one large unit — one handles light loads and the other stays on standby during maintenance.